Features 

Stable hematology analyzer combined with reliable hardware and intuitive software,for sure it is designed to be a easy operation diagnostic system with convenient data communicate interface,excellent performance.

Animal species: Canine, Bovine, Feline, Ovine, Equine, Simian, Porcine, Murine, and 4 user-defined 

speciesPrinciple: Impedance for WBC, RBC, PLT counting Compact design 

Throughput: 60 samples per hour 

3-part differentiation of WBC, 20 parameters +3 histograms 

3 counting modes: whole blood, capillary blood and prediluted 

Micro sample volume: 10 ul Built-in thermal printer Reagent:Diluent,Lyse,PB Cleanser,E-Z Cleanser 

12months warranty

Specification

General Features

Model 420C VET

Throughput  60 samples/hour

Channels 2 

Aperture diatmeter  WBC chamber:100um, RBC/PLT chamber:70um

Principle  Impedance for WBC,RBC,PLT; SFT method for HGB 20 parameters(including WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%,

Parameters RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR)

Histograms 3 histograms(including WBC,RBC,PLT histograms)

HGB lamp  LED 540nm

Sample volume Normal: 10ul, Prediluted: 20ul

Standard 

reagent Reagent Standard: Dilent: 20L, Lyse: 500ml 

Cleanser Standard: Probe cleanser: 50ml

Software

Calibration  Manual & auto calibration 

Counting modes Venous, capilary, prediluted 

Print Auto print, manual print 

LIS Support LIS 

Language English, Spanish,Italian,Portuguese, etc

Specifications

Input 10.4 inch touch scree(WML420C) 

Output  Internal printer, support external printer 

Printer paper  80×35mm 

Interface RS232 port, USB port, VGA port 

Storage 30,000 results with histogram 

Dimension  514mm×594mm×645mm 

Blockage clear High voltage, high pressure flush 

Net weight  23kg 

Performance

                                 


                               Carry-over rate
ParameterCV
WBC≤ 2%
RBC≤ 1%
HGB≤ 2%
PLT≤ 2%



                                   

                                  Background

ParameterBackground
WBC≤ 0.2×109/L
RBC≤ 0.02×1012/L
HGB≤ 1 g/L
HCT≤ 0.5%
PLT≤ 10×109/L





                          Precision

ParameterCVMeasurement range
WBC≤ 2.0%(4.0-15.0×109)/L
RBC≤ 1.9%(3.5-6.0×1012)/L
HGB≤ 1.9%(110.0-180.0g)/L
MCV≤ 0.4%(80.0-110.0)fL
PLT≤ 4.0%(100.0-500.0×109)/L






                          Linearity

ParameterMeasurement rangeCV
WBC(0-5.9×109)/L(±0.3×109)/L
(6.0-99.9×109)/L±5%
RBC(0-0.99×1012)/L(±0.05×1012)/L
(1.0-9.99×1012)/L±5%
HGB(0-99.0g)/L(±2.0g)/L
(100.0-300.0g)/L±2%
PLT(0-99×109)/L(±8.0×109)/L
100-999×109)/L±10%